Environmental Engineering Department at the College of Engineering, University of Baghdad, held PhD dissertation examination titled:

“Air-cathode desalination cells for simultaneous wastewater treatment, brackish water desalination, and power generation”

 

    By the student Abbas Hadi Abbas and supervised Prof.Dr. Mohanad J. M-Ridha on Thursday 12/11/2026, in the Environmental Engineering discussion hall. The examination committee consisted of Prof.Dr. Ahmed Abed Mohammed as Chairman, and the membership of  Asst.Prof.Dr. Haider Mohammed Abd-AlHameed, Asst. Prof. Dr. Ghufran Farouk Jumaa, Asst. Prof. Dr. Hussein Jabbar Kadhim, and Asst. Prof. Dr. Nabeel Majid Alaiwi. It is worth mentioning that the candidate holds the academic title of Professor and obtain a PhD by Research. After conducting the public discussion and listening to the student’s defense, the dissertation was accepted. It was summarized as follows:

Microbial desalination cells (MDCs) are bioelectrochemical systems that treat wastewater and desalinate water while producing energy using electroactive bacteria simultaneously. Focuses on how well microbial desalination cells (MDCs) can treat wastewater and remove salt from water at the same time. The goal of the project is to ascertain whether MDCs provide a practical, eco-friendly way to produce electricity and purify water. Air cathode microbial desalination cell (AMDC) is used in this study. The AMDC consisted of three chambers manode, desalination, and cathode with volumes of 2833 mL, 1416 mL, and 2833 mL, respectively These volumes were depending on design requirement. An anion exchange membrane (AEM) and a cation exchange membrane (CEM) were  used . Both the anode and cathode electrodes were graphite plates (90 mm × 90 mm × 3 mm). The cathode chamber was aerated using an air pump with air flow rate of 3.5 L/min.  Two 25 L plastic tanks were used, one sealed for wastewater and brackish groundwater. A multimeter is also used to measure the electricity using a resistor box of (10-10000 Ω). The system was operated first in batch mode for four runs with synthetic wastewater as anolyte and synthetic brackish water; then the system was operated in continuous mode for three runs with real municipal wastewater from Samarra city as anolyte and real artesian groundwater in Samarra city. Four batch runs were conducted with varying  intial synthetic anolyte COD concentrations and intial  total dissolved solids (TDS) concentrations in the desalination chamber, .  COD :TDS concentrions for Run 1 ,Run 2 ,Run 3 ,and Run4 were  500ppm: 2500ppm, 1000ppm: 5250ppm , 484ppm: 3570ppm,and  382ppm: 1600ppm, respectively  , then daily measured are achieved . The polarization curve for   run 1 showed a peak power density of 5.8 mW/m² and a current density of 24 mA/m², with an internal resistance of 643 Ω.  In Runs 2–4 the AMDC was operated in CCV mode using an external resistance of 500 Ω to evaluate electricity generation, anolyte COD removal, and brackish water TDS reduction. Run 3 showed the highest performance, with a peak current density of 25.06 mA/m², a power density of 5.087 mW/m², and a maximum COD removal efficiency of 45.04 %.Coulombic efficiency (CE), defined as the fraction of electrons recovered as current from the substrate, the max. CE was 1.65 %, 3.3 %, and 2.26 % for Runs 2, 3, and 4, respectively. The highest TDS removal efficiency (27.7%) was also observed in Run 3. The system was operated in continuous mode for three Runs (intial  anolyte COD conce. :  intial  desalintion TDS conce. were 709ppm: 4220ppm, 1179ppm:  3960ppm , and 743ppm :3560ppm for Run1, Run2 and Run3 respectively  then daily measured were  achieved  .  with Hydraulic retention time (HRT) of 3, 1.5, 0.75 days for wastewater and 1.5, 0.75, 0.375 days for groundwater at flow rates of 0.65, 1.3, and 2.6 mL/min, respectively, and  with wastewater and groundwater recycle of 100%. The results showed the maximum chemical oxygen demand (COD) removal of wastewater were 77.1%, 76.84%, and 77.52%,for Run1 , Run2, and Run3  respectively  at external resistance of 500 Ω. Polarization curves for the three runs showed a maximum power density of 7.674 mW/m2 and a current density of 30.74 mA/m2. The internal resistances were 1000, 1000, and 500 Ω for Run1, Run2, and Run3, respectively. The Response Surface Model (RSM) methodology was applied to batch and continuous experiments using the Design-Expert 12® software   For batch system ,the optimal COD removal was 80.72% with R2 reached 0.9759, and the optimal TDS removal  was 30.39% with R2 reached 0.7841 . For the continuous system the optimum was achieved to obtain 75.5 % of COD removal % with R2 reached 0.9973   at time of 96 h and optimum TDS removal % reached 30.1% with R² was 0.9965 at time of 240 h. The novelty of this study is :1. using distilled water as catholyte without addition of buffer solution to reduce the harmful effect of buffer additive such use phosphate to environments and without using expensive metal catalyst ,2. using real municipal wastewater of Samarra city as anolyte and real Samarra city groundwater as brackish water for desalination as special case study. (practical novelty) 3. using wastewater recycle in the stage of continuous treatment.

The recommendations of this dissertation:

This research project can be extended in the future to consider the followings:

  1. For batch mode, although promising, the results indicate that AMDC performance is sensitive to environmental and operational factors. More studies will be needed in order to enhance the system specifications and resolve problems such as membrane fouling and energy recovery efficiency.
  2. Research should be conducted further to improve the results for the continuous mode of operation (e.g. membrane structure, the use of catalysts, studies of membrane pollution management, etc.).
  3. Study the impact of different forms of the electrodes in the anode chamber on the AMDC efficiency.
  4. Study the impact of external resistance; and its effect on desalination efficiency.
  5. Scale-Up and Application: One of the main objectives is the development of scalable laboratory systems which can be applied in large-scale scenarios such as wastewater treatment and desalination.
  6. Dealing With Inherent Technical Challenges: Future studies will have to overcome several challenges that currently exist with the MDCs currently being used, namely:
  • Inner Resistor: the reduction of inner resistor will improve the performance of power output.
  • Membrane Stability: looking at ways to reduce membrane scaling and fouling, which reduce long-term operational stability.
  • Normalization: To facilitate comparison across different MDC settings, consistent modeling frameworks and standards should be established.
  1. Rates for Enhanced Removal of TDS: More studies have to be conducted in order to improve the desalination rates and efficiency observed in this experiment.

Comments are disabled.